. LabVIEW Real-Time 모듈. You also can use the Mini DisplayPort to add a local human machine. . In a cRIO, for example, the POWER LED should be solid green. 3. 2 by changing inheritence, etc. Using NI 9467 GPS module. Whether you are creating a new configuration, replacing or expanding your current CompactRIO System, or verifying that existing parts can be used in a different configuration. Your 9024 does not have this capability. Brand: National Instruments | Category: Controller | Size: 0. crio 9024-URGENT! MAX. Find many great new & used options and get the best deals for NI cRIO NI 9024 CompactRIO Controller / 800 MHz CPU, 512 MB DRAM, 4 GB Storage at the best. 0. To restore my CompactRIO (cRIO), sbRIO, PXI Real-Time controller, stand-alone USRP controller, or other real-time targets to factory default. 0 NI System Configuration Remote Support 15. Quanser Rapid Control Prototyping Toolkit® for NI LabVIEW™ Installation Guide 2. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy) —The cRIO‑9025 is an embedded real-time controller ideal for advanced control and monitoring applications. I have NI cRIO-9024 Real time controller connected on a chassis. Built a custom device in asynchronous execution mode . The controller automatically attempts to connect to the network using DHCP. In the General tab scroll down until you can read the information about Number of DMA Channels. NI CompactRIO을(를) 다운로드하고 지원 정보를 찾으십시오. enable:This is my first exposure to Labview so please bear with me. Member. 8-Slot, 1M Gate FPGA CompactRIO Chassis (Legacy) —The cRIO‑9102 is a rugged FPGA chassis that you can use to add C Series I/O modules to your distributed control or monitoring application. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. The included device driver communicates with the firmware to help you set up and control how the compatible CompactRIO Controllers operate. Power Connector 3. I recommend that you refer to the instruction in the Root:C:Program FilesNational InstrumentsNI-IndCom for CANopenFirmware_Update_Instructions. The cRIO-9002/9004 draws power from the power sourceMAX lists the cRIO controller as the model name of the controller followed by the MAC address, for example, NI-cRIO-907400802f10856. I'm currently working on a projekt including a cRIO-9024 target and I need to compile a DLL from a third party supplier. 『CompactRIO cRIO-9024 操作手順と仕様』―コントローラをネットワークに接続する方法や、コントローラの機能を使用する方法を説明しています。操作手順は、コントローラに同梱されています。 Re: cRIO 9024 USB stick not found? 06-30-2016 04:13 AM. , where I have no idea where to get these. I want the data to update in realtime (1Hz sine wave should complete one oscillation in one second on the chart, and at the output of hte NI-9264). User Manual 1. 5. So basically, 0x661 is a generic crash message, similar to "<Application> has encountered a problem and needs to close" on Windows. slot 3 = NI-9263. Hello I am new to real time acqusition and I am using cRIO 9024 with NI 9219 NI 9225 and NI 9215 for my data acqisition. I am using a cRio 9024, and 6 modules for signal input and signal output. As of LabVIEW Real-Time 8. To do this, since the "FP. C Series I/O Cable & Accessory Compatibility Guide. 255. Return to Home Page; Toggle navigation; Solutions. Hello, i currently have a problem with copying files to a USB-Stick connected to a NI 9024. It includes a Kintex-7 70T FPGA with LabVIEW FPGA Module support for advanced control and coprocessing. 4: NI-9978 4-pos Screw Terminal. chassis = cRIO-9073. please help. cRIO-905x Firmware and Additional Drivers includes a device driver as well as firmware for the cRIO-9052, cRIO-9053, cRIO-9054, cRIO-9055, cRIO-9056, cRIO-9057 and cRIO-9058 CompactRIO Controllers. The problem is whenever I start my cRIO-9072, I have to undeploy all my digital modules and redeploy it again in order for it to detect the digital output modules. Anyone can obtain information about the validity of a given certification by contacting the UL Customer Experience Center. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. Show More Description. 10-09-2013 07:15 AM - edited 10-09-2013 07:17 AM. NI ETS 2009부터 NI는 ETS OS를 지칭할 때 OS 버전 대신 LabVIEW 릴리스 번호를 사용하기 시작했습니다. You must connect Ethernet port 1 to configure the cRIO-9024. 4 Won't Compile LVAC. cRIO-9025 Front Panel 1. Format the cRIO in NI MAX. 0 which is same with that I made for. Starting with LabVIEW 2015, NI-RIO has. However, there's not a repeatable set of. We later transitioned to a 4-slot cRIO-9075 as our second-generation controller. National Instruments cRIO-9024 CompactRIO Controller- 512 MB DRAM, 4 GB Storage. Member. . cRIO-9024 cRIO-9025. ncd file will do for now. If a configure the custom device with no modules their is no problem to deploy to the cRIO. I am using a cRIO 9024. You can request repair, RMA, schedule calibration, or get technical support. Hi, I am trying to open the front panel of the VI on my cRIO-9024 through a remote computer. The following steps show how to install NI-VISA on your cRIO: 1. . 4 pos. National Instruments cRIO-9038 CompactRIO Controller- 2 GB DRAM, 8 GB Storage. Using incompatible versions may result in errors, or missing palettes or functions. The compilation and deployment works, but I can't change the state of my output on the card. 6以降およびLabVIEW 2015以降が必要です。The Quanser Q1-cRIO module can only be used with the NI cRIO-9024 controller with cRIO-9113 or cRIO-9114 chassis, or NI cRIO-9074 controller. Now I am working on NI 9222 ,NI cRIO-9024 and I want to measure EMG signal. NI GPIBコントローラおよびGPIBポートを備えたNI組込コントローラをサポートします。. The cRIO-9056 is a rugged, deployable controller for data acquisition and control applications. Now I want to use this kit to use with the cRIO-9022 (with the cRIO-9114 chassis). ** NIは、Phar Lapのサポートを、cRIO用はNI 2020ソフトウェアリリースで、PXI用はNI 2022ソフトウェアリリースで終了します。詳細については、Phar Lap RT OS EOLロードマップを参照してください。. Download All 0 Kudos Message 1 of 6 (4,582 Views) Reply. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. I am using a CRio 9024, running veristand 2017, outfitted with an NI 9862 CAN card to communicate with a pair of pump controllers using J1939 CAN protocol. Guess I need a. 0, FAT32), reb. Special Conditions for Hazardous Locations Use in Europe and Internationally. MAX recognizes all devices, so does Project Explorer. The recommended method for deploying a LabVIEW Real-Time startup executable is todo so through the LabVIEW Project . Pop up window appears to either discover 'Existing target or device' or add new target. 0およびドライバ をインストールしてLabVIEWで使用するには、以下の手順に従ってください。 特定のハードウェアデバイスをサポートするソフトウェアバージョンを確認するには、「サポートされているハードウェアとソフトウェア. コミュニティ. Dear all, I am new here, this is my first forum question. Supported Operating Systems. Today, after fixing the "chinese language issue" with the DistributedManager the situation is the following: 1. With thearinc & 1553 . 5. As the message says, this is likely showing up because the software installed on the target is a different version than the development environment you are attempting to connect to the target from. Open a service request. " LabVIEW: (Hex 0x80DF001E) The deployment. 1. 2, yet upon opening the application I am prompted with the following message:. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator; Hello, I am started to learn Labview and i want to communicate with CANopen (9881) module in FPGA interface,. Quanser Rapid Control Prototyping Toolkit® for NI LabVIEW™ Installation Guide 2. 1 . SNTPサーバと同期するようにコントローラーを構成するには、次の手順を行います。. I need to study the affect on temperature measurements of pt100, as i increase current passing through it. The CompactRIO real-time controller (NI cRIO-9024) has an 800 MHz industrial processor that balances low power consumption and powerful real-time control algorithms, signal analysis, and data logging. The cRIO-9012/9014 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO Certificate No. The cRIO‑9024 does not include. If you filled an entire 8 slot chassis with 9215 modules you would use about 12 MB/s. Open a service request. NI 9403 using FPGA as an input module help? best regards Alexander 9024. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. National Instruments cRIO-9035 CompactRIO Controller- 1 GB DRAM, 4 GB. 1. NI-cRIO 9024 장비와 인터넷 케이블로 소프트웨어 업데이트를 진행할때 에러메시지가 나타남니다. Order by Part Number or. The cRIO-9024 has a primary power input, V1, and a secondary power input, V2. Real. LabVIEW FPGA 모듈. I have a cRIO 9024 with an NI 9853 CAN module. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. ATE and Labview Consultant. vi on cRio controller and FPGA. Dear All, I'm having trouble setting up a cRIO-9024 and a CRIO-9014 (not at the same time) with the latest versions of Labview and Windows 10. html directory. 09-03-2015 04:05 AM. 1, LabVIEW Real-Time 15. Crio_9024: FPGA compilation error_resource overmapping_DSP48s 114. 2 and the subnet mask is 255. Pop up window appears to either discover 'Existing target or device' or add new target. This page is part of the CompactRIO System Accessory Compatibility Guide. All of control system was in FPGA. 6, CompactRIO real-time controllers using the VxWorks operating system can be configured to synchronize to SNTP servers. As the leader in eSource technology, CRIO enables remote monitoring and immediate. For more information,. LabVIEW 2011 SP1 FPGA Module or later. I have modified the example of scan interface VI according to my requirement and it is working conditionally. Our first NI controller was an 8-slot cRIO-9024. Open NI Measurement & Automation Explorer (MAX) and find your cRIO. How can I synchronize the 9024 rack and the 9068 rack? I have NI-TimeSync 1. 11. A valid service agreement may be required. Quanser Workstations Resources CD (includes User Manual and Quick Start Guide. . Removed support for cRIO-9012 and cRIO-9014 controllers. When I run the program I keep getting a Drive Fault (and also the LED turns red on the module), even though I have checked the connections. 3 N · m (11. Rate the cRIO-9024. 1. A valid service agreement may be required. Another option for you would be to reassign the PC #2 network card IP address to something in the range 169. Please help!software to programme the cRIO and 9505 - i. 0 etc. I am trying to a get clean 1Hz sine wave on a chart, and get a reasonably clean output from the NI-9264. There is no content, but it seems to be on the net. k-waris. Return to Home Page; Toggle navigation; Solutions. For example, I want to generate a 10-us delay. This software-designed controller features an FPGA and a real-time processor running the NI Linux Real-Time OS, which gives you access to the Linux community. (cRIO 9024+cRIO 9104) would a llow data tr ansmission . cRIO-9024 Front Panel 1 3 6 7 4 2 8 9 5 1. Real-Timeコントローラ: cRIO-9022、cRIO-9023、cRIO-9024、およびcRIO-9025; CompactRIO再構成可能シャーシ: cRIO-9111、cRIO-9112、cRIO-9113、cRIO-9114、cRIO-9116、およびcRIO-9118; 統合型CompactRIO Real-Timeコントローラ:. I got a brand new NI cRiO 9024 and several modules for data logging a few days ago. The POWER LED on the cRIO-9030 indicates which power input is in use, as shown in the following table. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. Since the reading/consuming frequency will be variable in my FPGA (it will depend on the values in the . However, when I manually change the current time on the cRIO 9024, the EtherCAT slave stops working: In the DSM, all of its channel values are completely frozen, while the EtherCAT master's channels still. I would like to save measured data from modules into the txt files but I would like to do it in some time period for desire time. Free. QUANSER. I want to use c-Series modules with the maximum sample rates for high resolution measurements. 2011 SP1. NI-PS-14/15/16/17 Side Mount Bracket Installation Guide. NI-PS-14/15/16/17 Side Mount Bracket Installation Guide. Figure 17 NI cRIO-9024 real-time controller, from [22]. Note The NI-XNET software supports only National Instruments CAN, FlexRay, and LIN hardware products. Follow the instructions in Real-Time and FPGA Front Panel and Block. This article explores the causes of a flashing status light on a CompactRIO controller. Both compact RIOs work fine on an Labview 16 on. The budget is not a problem. Engineers at the University of Zürich have used the WR design to build a C-series module for the cRIO platform, The cRIO-9024 filters and regulates the supplied power and provides power for the C Series modules. NI R 시리즈 다기능 RIO 디바이스 드라이버. x. - You have atleast 2 voltage inputs on your module available. cRIO-9024 is just the controller. Order by Part Number or Request a Quote. Join Product iQ. I also wanted to point out that the Xilinx tools have nothing to do with the difference between the cRIO-9004 and the cRIO-9024. Integrated CompactRIO Real-Time Controller: NI cRIO-9081, NI cRIO-9082, NI cRIO-906x, and NI cRIO-903x; LabVIEW FPGA 2014 is required to build and deploy a bitstream with NI 986x modules in the project. cRIO-9111, cRIO-9112, cRIO-9113, cRIO-9114, cRIO-9116, or cRIO-9118. When building the standalone real time application and running it as startup, something stops working. It may also appear as «Generic USB-EEM Adapter». Rated 4. I am an intermediate LV user, and am developing a control system using the built-in RT control template provided with LV. s. 0. I used Crio 9024 with 9116 chassis with Labview 2009 and it works fine. Figure 2. Member. but it'sNI cRIO-903xまたはNI cRIO-906xと共にNI Compact RIO 17. I'm surprised by the cRIO executable starting time after reboot. cRIO 9068 runs Linux, so it should be OK with eth0/eth1 in the same subnet. Options. The cRIO-9024 is an embedded real-time controller ideal for advanced control and monitoring applications. When building the standalone real time application and running it as startup, something stops working. xx/u:/ in the address bar, where xx. Many teams struggle to manage product quality within shorter and shorter time-to-market windows, but best-in-class test organizations are leading the way. LabVIEW will automatically choose the correct Xilinx Compilation Tools needed based on hardware. A valid service agreement may be required. So I already program basic blockdiagram(see picture) ,And I stuck in the way to export the whole data that I measure . Engineers at the University of Zürich have used the WR design to build a C-series module for the cRIO. The cRIO-9024 has a primary power input, V1, and a secondary power input, V2. 254. cRIO-9030 cRIO-9031 cRIO-9033 cRIO-9035 cRIO-9036 cRIO-9038. All, I have a cRIO-9024 with an NI 9853 and I'm trying to configure and control an Emerson Unidrive SP using CAN port 0. We have a program running on CompactRIO cRIO-9024, no chassis. This should be under Remote Systems. Use this guide to select the correct MXI-Express cable for your CompactRIO Controller. png. It is designed to easily interface with more than 85 Quanser controls experiments. CompactRIO cRIO-9074XT NI cRIO-907x 1 3 5 2 4 6 7 8 POWER FPGA STATUS USER1 TE CABLES WHEN TIONS SAFE MODE CONSOLE OUT IP RESET NO APP USER1 NO FPGA LINK LINK 10/ 100 10/ 100 RESET INPUT. In case, if I am executing a VI program in the cRIO RT (Real-Time) environment. See system specifications on reverse. The IP address must be on a different subnet than the . It features an industrial 800. 2. Eventually, the data logger will be used in a hardware in the loop system, another topic I am new to. The controller provides. The controller used is cRIO-9024 with cRIO-9118 chassis and NI-9403 c series module. 1, gateway of 255. 解决方案. The National Instruments cRIO-9024 Real-Time Controller is part of the high-performance CompactRIO programmable automation controller platform. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. FPGA and Real-Time target (e. I created a project and ran Host. EtherCAT is an Ethernet-based deterministic synchronized protocol. I have tried using Labview 18, and have just tried version 19, but without success. 919 809 5227. 1f2) that uses a NI-9870 (RS-232) module under the FPGA at the cRIO-9024/NI-9114 level plus a second NI-9870 module under the FPGA of an attached NI-9144 EtherCAT. The cRIO-9046 is a rugged, high-performance, customizable embedded controller that offers Intel Atom dual-core processing, NI-DAQmx support, and an SD card slot for data-logging, embedded monitoring, and control. The cRIO-9024 (Part number: 781174-01, 193965E-01L ) is a high-performance Controller by National Instruments. Hello all, I have a Sick lms 100 laser scanner connected to the one of the 2 TCP/IP ports of a CRIO 9024 and wanna get data from the Sick. Hello all, im trying to program an NI 9403 using labview and crio9024, but first of all i should delete priviously simulated hardwares. g. Rated 0 /5 based on 0 ratings. and they didn't recognize the ISE10. The included device driver communicates with the firmware to help you set up and control how the compatible CompactRIO. NI is now part of Emerson. If you're unable to see the serial port, ensure that the correct version of the driver is installed. The cRIO-9002/9004 filters and regulates the supplied power and provides power for all of the I/O modules in the chassis. Hello Ali_H, I am using labview 2013 with RIO0-7851R, and I met the same problem, that is the code is eating the DSP48s but keeping the slice LUT and registers at low consumption. 0 installed. 2. However, when I manually change the current time on the cRIO 9024, the EtherCAT slave stops working: In the DSM, all of its channel values are completely frozen, while the EtherCAT master's channels still oscillate around the noise floor. Member. 35 Figure 18 NI 9870 4-Port, RS232 serial interface module and the four-slot, cRIO NI-9113 chassis, from [22]. I have LabView 21 on my host computer. arinc800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)—The cRIO‑9024 is an embedded real-time controller ideal for advanced control and monitoring applications. Member. I uploaded the xml file required to detect this third party slave device, and it was a success. To access the data contained on the USB flash drive connected the Compact RIO, open an Internet Explorer browser window from a networked host machine and enter ftp://xx. I want to share the VI that handles the four serial ports between the two instances. NI CompactRIO 디바이스 드라이버. It is designed to easily interface with more than 85 Quanser controls experiments. Reference this information to ensure that you install the correct toolkit version when upgrading or updating your system or software. The cRIO-9030 filters and regulates the supplied power and provides power for the C Series modules. If you are using the cRIO-9024 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment. These a. I am using Veristand with a compiled model from Simulink to make my control. Alternatively, you may trigger the acquisition via a shared variable over Ethernet; in this case you need a computer to control the cRIO remotely. 0. Each cRIO-9012/9014 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ≤ 70 °C. Where is Wesley's Courier located? Wesley's Courier is located at 808 Colville Rd, Victoria, BC. I have the Indsutrial Communication for CANOpen 1. 9 /5 based on 13 ratings. Options. I want to EtherCAT Master using Beckhoff C6015-0010 (C9900-C583) 05-02-2018 03:40 AM. From what you've said, logging memory usage. I've been having trouble with controlling a DC motor using the ni 9505 on cRIO 9024. Side mounting kits are capable of panel/wall mount and DIN-rail mount. 0. I find this confusing since the ethernet ports should have no power. The solution is the main thing. Note: NI will remove support for Phar Lap for cRIO in the NI 2020 Software Release and for PXI in the NI 2022 Software Release. We would like to show you a description here but the site won’t allow us. Windows 10. ( stand alone without a host computer) The CompactRio is connected to a network drive( like \\\\XXX. 12-24-2016 05:41 AM. Options. RT NI cRIO 9024. | CRIO is a health tech company helping pharma, biotech, research sites, and academic research centers streamline regulatory workflows with one system that enables a single point of data capture. I'm developing a project by NI cRIO 9024 and NI 9870 to implement the instrument control. NIの集録および信号調整デバイスをサポートします。. ), displaying sensor values (displacement, force) and controlling some situations, not so risky. System tags can be found in the following places: PXI Chassis: Above or below the serial number label on the back or bottom of the chassis. 254. I was trying to avoid doing a custom device or FPGA, and found a work around using the 9401 in. ご希望の項目を選択してください。. To format the disk and reinstall software To reset my cRIOfrom NI Measurement and Automation Explorer (NI MAX) without having to install any software (LabVIEW, LabVIEW Real-Time, cRIO driver) The method. I am running Veristand 2014, cRio 9024, 6modules, and running in Scan Engine. NI 9403 using FPGA as an input module help? best regards Alexander 9024. I am using the digital modules to drive some devices. 4 . All VIs for UART you find in UART 8N1 (FPGA). Try searching for what you need. So the project "PQ Starter Kit" should be opened in the Labview Project Explorer and be saved as a. g. It provide no download like X13. To. (subnet 255. 11-21-2010 01:09 AM. If you are in home network which has DHCP server ,reset your IP using Hardware switch and restart your system. I am trying to read a spreadsheet with the Read Delimited Spreadsheet VI. To resolve this issue, work through the troubleshooting steps below: Check that the controller's power supply is working as expected. I'm having trouble setting up a cRIO-9024 and a CRIO-9014 (not at the same time) with the latest versions of Labview and Windows 10. お問い合わせ. Reboot the device. Programming With LabVIEW. Fiddling with a pen or small screwdriver to switch USER1 isn't what I call "user friendly". x. 400 MHz CPU, 128 MB DRAM, 2 GB Storage, Extended Temperature CompactRIO Controller (Legacy) —The cRIO‑9014 is an embedded real-time controller ideal for advanced control and monitoring applications. As you may read in my initial posts I could not discover the C modules with the ScanEngine, but they showd up in the FPGA project. NI is now part of Emerson. (Best practice without the Software modules)The cRIO-9038 is a rugged, fanless, embedded controller that you can use for advanced control and monitoring applications. Without knowing anything else about your project, my first thought is that the name of the cRIO changed and thus any variables pointing to it are still looking for the old name. zip 37 KB. To help you achieve the specified analog module accuracies for cRIO systems containing a cRIO-9022 or cRIO-9024 and/or cRIO-911x we recommend you adhere to the following guidelines (note. Options. So, I. CompactRIO cRIO-9012/9014 このドキュメントでは、NI cRIO-9012/9014リアルタイム組込コントローラをネット ワークに接続する方法と、コントローラの機能の使用方法を説明してい. 65 MB. The Quanser Q1-cRIO is a C Series module for the NI cRIO-9024 controller and NI cRIO-9113 backplane. The programming setting is as follows:CompactRIO cRIO-9024. Currently, 1 device is plugged into the 9870 card and communicates properly via serial/VISA with the controlling computer connected to the cRIO via ethernet. I have 2 cRIO-9024 units, with the same software sets installed: NI-CompactRIO 15. Currently, I am able to run the VI with no problems with. Hello, I'm trying to control a 3rd party servo drive via EtherCAT: Hardware: Master: NI-cRIO 9024 Slave: Beckhoff AX5203 Software: LabVIEW 2013 SP1 (32-bit) NI-Industrial Communications for EtherCAT 2. For this I need to install RT. My computer and cRio are connected to the same. To synchronize the data we have the idea to run the 9024 as Master and export a 25kHz trigger signal on the Digital output from an additional 9205. If you are using the cRIO-9012/9014 in Gas 8-Slot, Virtex-5 LX110 FPGA CompactRIO Chassis (Legacy) —The cRIO‑9118 is a rugged FPGA chassis that you can use to add C Series I/O modules to your distributed control or monitoring application. . Stick is formatted to. 6, CompactRIO real-time controllers using the VxWorks operating system can be configured to synchronize to SNTP servers. The Quanser Q1-cRIO is a C Series module for the NI cRIO-9024 controller and NI cRIO-9113 backplane. arinc & 1553 . CompactRIO real-time controllers enable you to directly deploy your control algorithm and run the code National Instruments cRIO-9024 CompactRIO Controller. (subnet 255. I am using Labview 2012, CRIO 9024 as the master device, Kuka Youbot(not from NI) as the Ethernet Slave device, with a platform and an arm. This document describes how to install the NI cRIO-9024 real-time embedded controller on a CompactRIO chassis; connect the controller to a network; connect power; configure IP settings; install software; and use some of the features of the controller. The NI 9908 and NI 9909 are accessory kits for mo unting a stand-alone cRIO-902 x controller on a DIN rail or panel, respectively. 1 KudoHello, Sorry to say you cannot use that EXE directly due to the cRIO-9024 doesn't have a existing FPGA Bitfiles. My cRIO is configured to allow TCP/IP protocol, The VI is visible, and I have made my project into a source distribution on my. As shown in the first picture, when I use this code in the host VI for some reason all the digital outputs on the NI9401 go to high and then quickly go low. I want to synchronize this master time reference with the RT System Time on a cRIO-9024 controller (slave). This document will help you achieve the highest measurement quality when using high-power CompactRIO systems that contain a cRIO-9022 or cRIO-9024 controller and/or a cRIO-9111, cRIO-9112, cRIO-9113, cRIO-9114, cRIO-9116, or cRIO-9118 reconfigurable embedded chassis (referred to inclusively as the cRIO-911x). I am using cRio 9024, Can Breakout box and NI 9881 to communicate with CANopen system. The following table shows the supported system type and the minimum software version required to use the CANopen VIs with the NI PXI-8531. I have NI cRIO 9024 and a Cseries Module NI 9263 (output voltage module). Aerospace, Defense, & Government. 0. When running the system in development mode (pressing the run button), everything seems to work fine. xx.